F2
Severin
Display Module / Power Supply Fault
F2 appears and the display backlight or segments flicker or go blank intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failing low-voltage power supply on PCB, Loose display connector, Damaged LED/LCD display module, Hairline cracks on control PCB
How to Fix / Troubleshooting
Safety first: Disconnect mains power before opening the control housing.
- 1. Remove control panel: Unclip or unscrew the front control panel to access the display PCB.
- 2. Check connectors: Reseat the display connector and any low-voltage harnesses. Ensure no pins are bent.
- 3. Inspect for damage: Look for burnt components, especially small transformers, regulators, or capacitors on the control board.
- 4. Test supply voltage: With the unit powered (only if you are competent and using insulated probes), measure the low-voltage output feeding the display (often 5V or 12V DC). If unstable or missing, the power supply section is faulty.
- 5. Replace display or PCB: If the supply is good but the display remains faulty, replace the display module. If the supply is bad, replace the main control PCB.
- 6. Reassemble and test: Refit the control panel and verify that F2 is cleared and the display is stable.
If you are not experienced with live electrical measurements, have a technician perform the voltage checks and board replacement.