H2
Severin Ambient Temperature Out-of-Range Protection

H2 appears and the freezer may shut down or run at reduced capacity during very cold or very hot ambient conditions.

Advertisements

Possible Causes

Ambient sensor detecting temperature outside design range, Freezer installed in unheated garage or very hot room, Faulty ambient NTC sensor, Control board misinterpreting ambient readings

How to Fix / Troubleshooting

Safety first: Always unplug the freezer before accessing sensors or control boards.

  • 1. Check installation location: Verify that the freezer is installed within the ambient temperature range specified in the Severin manual (climate class). Move it to a more suitable room if necessary.
  • 2. Inspect ambient sensor: Locate and test the ambient NTC sensor as described for E3. Replace if readings are incorrect.
  • 3. Reset control: After correcting ambient conditions or replacing the sensor, unplug the freezer for 10 minutes, then reconnect to clear H2.
  • 4. Monitor: Observe operation over 24 hours. If H2 persists in a proper environment with a good sensor, the control board may be faulty and require replacement.