E6
Westinghouse Door Switch / Door Sensor Fault

Freezer shows E6 and interior light or fan may not operate correctly; control panel may be unresponsive.

Advertisements

Possible Causes

Failed mechanical door switch, Broken door switch actuator, Damaged door switch wiring, Faulty control board door input

How to Fix / Troubleshooting

Safety: Disconnect power before removing the door switch or control panel.

Steps:

  • Locate the door switch: On most Westinghouse freezers, the switch is in the door frame near the top or side, activated by the door closing.
  • Check operation: Press the switch plunger by hand. The interior light should turn on/off (if power is temporarily restored for this test). If not, unplug again and continue.
  • Remove and test switch: Pry the switch out carefully with a plastic tool. Disconnect the wires and test continuity with a multimeter. The switch should change from open to closed when pressed.
  • Inspect wiring: Look for loose connectors or broken wires in the door frame area.
  • Replace faulty switch: Install a new OEM Westinghouse door switch. Ensure wires are firmly connected and the switch snaps securely into the frame.
  • If switch and wiring are good: The control board input circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements