Westinghouse Loose Components / Tubing Vibration

Freezer makes a loud rattling or clanking noise when running.

Advertisements

Possible Causes

Refrigerant lines touching cabinet, Loose condenser coil, Loose fan shroud or panel, Items vibrating against interior walls

How to Fix / Troubleshooting

Safety: Unplug the freezer before adjusting any components.

Steps:

  • Check interior: Ensure baskets and food packages are not touching the evaporator cover or fan housing.
  • Inspect rear compartment: Look for copper tubing or condenser lines touching each other or the cabinet. Gently bend them apart and insert foam spacers if needed.
  • Tighten hardware: Tighten any loose screws on the condenser fan shroud, compressor mounting bracket, and rear cover.
  • Level the unit: Adjust leveling feet so the freezer sits solidly on the floor without rocking.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements