Westinghouse Long Run Time / Inefficient Operation

Freezer runs continuously and rarely shuts off, though it may still reach low temperatures.

Advertisements

Possible Causes

Door gasket leaking warm air, Condenser coils dirty, Freezer located in very hot environment, Internal air leaks around liner or drain plug

How to Fix / Troubleshooting

Safety: Unplug the freezer before cleaning or adjusting components.

Steps:

  • Inspect door gasket: Close a sheet of paper in the door at several points. If it pulls out easily, the gasket may be leaking. Replace the gasket if cracked or deformed.
  • Clean condenser: Vacuum and brush dust from the condenser coils and fan area.
  • Check location: Ensure the freezer has adequate clearance around it and is not in direct sunlight or next to heat sources.
  • Check drain plug and cabinet seams: Make sure the drain plug (if present) is fully seated and that there are no gaps in the liner or cabinet.
  • Monitor: After corrections, allow 24 hours and observe run time. If it still runs nearly nonstop with correct temperature, have a technician check system efficiency.