E17
Baxi External Control Input Error

Furnace indicates external thermostat or control signal fault, will not respond to room thermostat

Advertisements

Possible Causes

Open-circuit room thermostat wiring, Faulty Baxi wired controller, Incorrect bridging of thermostat terminals, PCB input fault

How to Fix / Troubleshooting

Safety: Isolate power before working on control wiring.

  • Check thermostat: Verify that the room thermostat or Baxi controller has power and is calling for heat.
  • Inspect wiring: At the furnace terminal strip, check that the thermostat wires are secure and not damaged. Tighten loose screws.
  • Test by bridging: Temporarily fit a link across the room thermostat terminals at the furnace (per Baxi wiring diagram). If the furnace now responds, the external control or its wiring is faulty.
  • Restore correct wiring: Remove the temporary link and repair or replace the thermostat/control as needed.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Thermostat / Baxi Controller
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements