Baxi

Baxi Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Furnace fails to ignite, burner does not light, ignition sequence aborts after a few attempts
Ignition Lockout
E02
Furnace locks out shortly after ignition, burner lights briefly then shuts down
Flame Detection Failure
E03
Furnace attempts to start but shuts down with fan running, no ignition, flue fan may cycle
Flue Fan / Air Pressure Switch Fault
E04
Furnace shuts down with overheat indication, flow temperature rises rapidly then burner cuts out
Primary Heat Exchanger Overheat / High Limit Trip
E05
Furnace displays flow temperature sensor fault, may not start or may run erratically
Flow NTC Sensor Failure
E06
Furnace shows return temperature sensor fault, may short-cycle or lock out
Return NTC Sensor Failure
E07
Furnace indicates flue gas sensor or flue thermostat fault, may shut down during operation
Flue Temperature Sensor / Thermostat Trip
E08
Furnace shows low water pressure or water pressure switch fault, will not fire
Low System Pressure / Water Pressure Switch Open
E09
Furnace indicates gas valve or gas supply fault, no ignition despite fan and spark
Gas Valve Control Failure
E10
Furnace shows fan fault, fan does not start or runs erratically during startup
Combustion Fan Failure
E11
Furnace displays communication error between user interface and main PCB, controls unresponsive or blank
Control PCB Communication Fault
E12
Furnace shows domestic hot water sensor fault (on combi-style furnace/boiler units), hot water unstable or unavailable
DHW NTC Sensor Failure
E13
Furnace indicates condensate fault, may lock out during wet or freezing conditions
Condensate Drain Blockage / Freeze Protection Trip
E14
Furnace shows flame loss during operation, burner repeatedly lights and goes out
Flame Instability / Intermittent Flame Signal
E15
Furnace indicates fan speed error, fan runs but speed feedback is out of range
Fan Speed Control / Hall Sensor Fault
E16
Furnace shows flow switch or flow sensor fault (on systems with flow detection), burner will not fire for heating
Primary Flow Switch / Turbine Sensor Failure
E17
Furnace indicates external thermostat or control signal fault, will not respond to room thermostat
External Control Input Error
E18
Furnace shows power supply or polarity error, may not start or may behave erratically
Mains Supply / Polarity Fault
E19
Furnace indicates EEPROM or configuration error, may lock out after power-up
PCB Configuration / Memory Fault
E20
Furnace shows safety chain open, safety thermostat or limit circuit not closed
Safety Thermostat / Limit Circuit Open
Symptom
Domestic hot water temperature fluctuates or runs hot then cold on a combi-style Baxi furnace/boiler
Unstable DHW Temperature Control
Symptom
Furnace emits a whistling or high-pitched noise during operation
Gas Flow or Airflow Resonance
Symptom
Furnace fan runs continuously even when there is no heat demand
Fan Overrun / Stuck Relay
Symptom
Furnace frequently loses pressure and needs topping up often
Chronic Pressure Loss
Symptom
Furnace frequently short-cycles, turning on and off every few minutes without reaching set temperature
Short Cycling / Poor Heat Transfer
Symptom
Furnace ignites with a loud boom or pop
Delayed Ignition
Symptom
Furnace leaks water from the bottom of the casing or from pipe connections
Internal Water Leak
Symptom
Furnace locks out intermittently during windy weather
Wind-Induced Flue Disturbance
Symptom
Furnace makes loud banging or knocking noises when starting or stopping
Kettling / Water Hammer in Primary Circuit
Symptom
Furnace produces a burning smell or plastic smell when running
Overheating Components / Foreign Material on Heat Exchanger
Symptom
Furnace runs but produces no heat to the home, radiators or ducts remain cold
No Heat Output Despite Burner Operation
Symptom
Furnace runs but room temperature overshoots or undershoots the thermostat setting
Poor Temperature Control / Thermostat Calibration Issue
Symptom
Furnace starts but shuts down after a few seconds without showing an error code
Early Flame Failure / Safety Trip
Symptom
Furnace trips the household RCD or blows fuses when starting
Electrical Short or Earth Leakage
Symptom
Furnace vibrates excessively or causes rattling in the flue or casing
Mechanical Vibration / Imbalanced Fan
Symptom
Furnace will not start at all, no lights or display
No Power / Dead Appliance
Symptom
Radiators heat unevenly, some remain cold even though furnace is running normally
Poor System Balancing / Sludge Blockage
Advertisements