E11
Defro
Return Water Temperature Sensor Error
E11 error; controller indicates return temperature sensor fault
Advertisements
Possible Causes
Defective return NTC sensor, Loose or corroded connector, Sensor not properly clamped to pipe, Broken cable
How to Fix / Troubleshooting
Safety: Let pipes cool before handling sensors.
- Find the return temperature sensor clipped or strapped to the return pipe near the boiler.
- Ensure it is firmly attached with thermal paste or a tight clamp for good contact.
- Inspect the cable for mechanical damage and verify the plug is fully seated on the control board.
- If you can measure resistance, compare with Defro's NTC chart at known temperatures.
If the sensor is out of specification or intermittent, replace it with a genuine Defro‑compatible NTC sensor.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Return Temperature Sensor (NTC)
Check Price on Amazon