Defro

Defro Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E01
Controller displays E01 and the furnace does not start the ignition sequence
Ignition Failure – No Flame Detected at Start
E02
E02 displayed and furnace shuts down shortly after ignition attempt
Flame Loss During Operation
E03
E03 error and furnace stops; display may indicate overheat or high boiler temperature
Overheat Protection Activated
E04
E04 displayed; furnace does not start fan or ignition sequence
Exhaust Fan / Draft Fan Failure
E05
E05 error and furnace stops; controller may show flue temperature fault
Flue Gas Temperature Sensor Fault
E06
E06 displayed; furnace does not respond to temperature changes or shows unrealistic boiler temperature
Boiler Temperature Sensor Error
E07
E07 error; controller indicates hopper or fuel temperature alarm
Fuel Hopper Temperature Overlimit
E08
E08 displayed; controller indicates feeder or auger fault and fuel is not being delivered
Screw Feeder (Auger) Jam or Motor Fault
E09
E09 error; controller indicates low water pressure or lack of water in system
Low System Pressure / Water Shortage
E10
E10 displayed; controller indicates circulation pump fault or no flow
Heating Circuit Pump Failure
E11
E11 error; controller indicates return temperature sensor fault
Return Water Temperature Sensor Error
E12
E12 displayed; controller indicates room thermostat communication or sensor error
Room Thermostat / Room Sensor Fault
E13
E13 error; controller indicates lambda sensor or O2 regulation fault (on Defro models with lambda control)
Lambda (Oxygen) Sensor Fault
E14
E14 displayed; controller indicates fan speed error or tachometer fault
Combustion Fan Speed Feedback Error
E15
E15 error; controller indicates door or hatch open
Door / Service Hatch Switch Open
E16
E16 displayed; controller indicates power supply or internal electronics error
Control Board Power Supply Fault
E17
E17 error; controller indicates buffer tank sensor fault (for systems with buffer/accumulator tank)
Buffer Tank Temperature Sensor Error
E18
E18 displayed; controller indicates DHW (domestic hot water) sensor fault
DHW Cylinder Temperature Sensor Error
E19
E19 error; controller indicates communication fault with expansion module or remote panel
Communication Bus Error
E20
E20 displayed; controller indicates pellet/coal out or no flame due to lack of fuel
Fuel Depletion / No Fuel Supply
Symptom
Ash pan fills very quickly and ash is unusually coarse or contains unburned fuel
Inefficient Combustion / Incomplete Fuel Burn
Symptom
Boiler pressure rises excessively during heating and safety valve discharges water
Expansion Vessel / Safety Valve Issue
Symptom
Buttons on the Defro controller do not respond or respond intermittently
Keypad / Control Panel Fault
Symptom
Condensation or water dripping from flue connection and back of furnace
Condensation in Flue / Low Return Temperature Corrosion Risk
Symptom
Controller display is blank or unreadable, but power is present at the unit
Display / User Interface Failure
Symptom
Frequent tripping of the main fuse or circuit breaker when furnace starts
Electrical Overload / Short Circuit
Symptom
Furnace casing or control panel becomes excessively hot to the touch during operation
Overheating of Casing / Insulation Degradation
Symptom
Furnace frequently shuts down and restarts, with large temperature swings
Short Cycling / Poor Control Tuning
Symptom
Furnace makes loud banging or knocking noises in the pipes when heating
Water Hammer / Boiling in Heat Exchanger
Symptom
Furnace runs but radiators remain lukewarm or cold, especially on upper floors
Insufficient Heat Output / Poor Circulation
Symptom
Room thermostat calls for heat but furnace does not start; display shows standby with no error code
Control Logic / External Control Inhibit
Symptom
Strong smoke or soot deposits visible at chimney outlet and on nearby surfaces
Incomplete Combustion / Sooting
Symptom
Strong tar or creosote smell around furnace and in boiler room
Low‑Temperature Operation / Tar Formation
Symptom
Unusual grinding or squealing noise from the screw feeder area during operation
Mechanical Wear or Obstruction in Screw Feeder
Symptom
Visible smoke leakage from furnace doors or joints into the boiler room
Flue Gas Leakage / Poor Chimney Draft
Symptom
Water leaking from under the furnace or from boiler casing joints
Boiler Water Leak