Short Cycling / Poor Control Tuning
Furnace frequently shuts down and restarts, with large temperature swings
Advertisements
Possible Causes
Oversized boiler for system, Incorrect hysteresis settings in controller, Buffer tank not used or undersized, Room thermostat placement issues
How to Fix / Troubleshooting
Safety: Adjust only user‑accessible settings; do not change service parameters without guidance.
- Review the boiler temperature setpoint and hysteresis in the Defro controller; increase hysteresis slightly to reduce cycling.
- If using a room thermostat, ensure it is placed away from direct sunlight, drafts, or heat sources.
- Consider enabling or optimizing buffer tank control if installed.
- Check that radiator valves are not all nearly closed, which can cause rapid temperature rise.
For persistent short cycling, consult a heating engineer to evaluate boiler sizing and system design.