E17
Defro Buffer Tank Temperature Sensor Error

E17 error; controller indicates buffer tank sensor fault (for systems with buffer/accumulator tank)

Advertisements

Possible Causes

Defective buffer NTC sensor, Sensor not inserted properly in tank pocket, Cable damage between tank and boiler, Wrong sensor type installed

How to Fix / Troubleshooting

Safety: Allow tank fittings to cool before touching sensors.

  • Locate the buffer tank sensor in the tank immersion pocket or strapped to the tank surface.
  • Check that it is fully inserted and secured.
  • Inspect the cable route for mechanical damage or loose junctions.
  • Confirm that the sensor type matches the Defro controller requirements (NTC value).

Replace the sensor if resistance readings are out of range or intermittent.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Buffer Tank Temperature Sensor
Check Price on Amazon