A19
IVT Control power supply instability

Furnace shows power supply error; random resets or control lockups

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low or fluctuating mains voltage, Failing internal power supply on IVT control board, Loose neutral or ground connection, Electrical noise from other equipment

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before inspecting electrical connections.

  • Check mains supply: Verify that the furnace is on a dedicated circuit with correct voltage and breaker size. Look for signs of tripped breakers or loose connections in the panel (by a qualified electrician).
  • Inspect terminal block: Inside the furnace, check the L/N/PE terminals for tight screws and no discoloration or burning.
  • Look for moisture: Ensure there is no condensation or water ingress on the control board or wiring that could cause shorts.
  • Monitor operation: After tightening connections, restore power and observe. If the control still resets randomly, the internal power supply on the control board may be failing.

Control board replacement should be carried out by an authorized IVT technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

IVT main control board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements