IVT

IVT Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
A01
Furnace will not start; no burner ignition, lockout indicated on IVT control display
Ignition failure lockout
A02
Burner lights briefly then shuts down; multiple failed ignition attempts before lockout
Flame detection failure
A03
Furnace attempts to start but shuts down during pre-ignition; combustion fan runs briefly then stops
Combustion air fan fault
A04
Furnace shuts down shortly after ignition; display indicates overheat or high limit trip
Primary heat exchanger overheat
A05
Furnace display shows low water pressure; burner does not start (for IVT hydronic furnace/boiler models)
System water pressure low
A06
Furnace display shows high water pressure; safety valve may discharge water (hydronic models)
System water overpressure
A07
Furnace locks out with flue gas temperature error; burner stops during operation
Flue gas overtemperature
A08
Furnace display indicates return temperature sensor fault; unit may run at reduced output or shut down
Return water temperature sensor failure
A09
Furnace display indicates flow temperature sensor fault; burner may not modulate correctly
Flow water temperature sensor failure
A10
Furnace shows outdoor sensor error; weather-compensated control not functioning correctly
Outdoor temperature sensor failure
A11
Furnace indicates circulation pump fault; no flow through system, radiators remain cold
Heating circulation pump failure
A12
Furnace display shows domestic hot water (DHW) sensor error; unstable or no hot water on combi models
DHW temperature sensor failure
A13
Furnace shows gas valve error; no gas flow to burner despite ignition attempts
Gas valve actuation failure
A14
Furnace indicates air pressure switch error; combustion fan runs but burner does not start
Air pressure switch / differential pressure fault
A15
Furnace display shows flue gas sensor error; unit may shut down or run at reduced output
Flue gas sensor failure
A16
Furnace indicates condensate fault; unit shuts down during operation (condensing models)
Condensate drainage failure
A17
Furnace shows communication error between user interface and main control; display may be blank or show dashes
Control communication failure
A18
Furnace indicates thermostat/room sensor error; heating does not respond correctly to room temperature
Room thermostat or room sensor fault
A19
Furnace shows power supply error; random resets or control lockups
Control power supply instability
A20
Furnace indicates safety chain open; unit will not start
Safety interlock circuit open
A21
Furnace shows fan speed error; circulation blower not reaching commanded speed
Circulation fan speed control fault
A22
Furnace indicates frost protection / anti-freeze error; system may not protect against freezing
Frost protection function failure
A23
Furnace shows sensor calibration error; temperatures or pressures appear unrealistic
Sensor calibration / plausibility fault
A24
Furnace indicates service interval exceeded; reminder for maintenance
Scheduled maintenance reminder
A25
Furnace indicates flue gas recirculation or CO risk; unit shuts down
Flue gas recirculation / combustion air contamination
Symptom
Domestic hot water temperature fluctuates or runs hot then cold (IVT combi/hydronic with DHW)
Unstable DHW temperature control
Symptom
Furnace causes a metallic or chemical smell in the home
Contaminated combustion air or heat exchanger issue
Symptom
Furnace emits a burning smell when running
Overheating components or dust burn-off
Symptom
Furnace fan runs but burner does not light and no error code is displayed
No ignition without fault reporting
Symptom
Furnace frequently trips the household circuit breaker
Electrical overcurrent / short circuit
Symptom
Furnace is unusually noisy in flue area; whistling or roaring from vent
Flue gas flow noise / resonance
Symptom
Furnace leaks water around the base during operation
Condensate leakage
Symptom
Furnace makes loud banging or booming noise at startup
Delayed ignition / burner light-off noise
Symptom
Furnace produces a high-pitched whine or squeal during operation
Blower or combustion fan bearing noise
Symptom
Furnace runs but produces no heat; supply air is cold
Burner not firing with fan-only operation
Symptom
Furnace runs continuously and overheats the house
Runaway heating / thermostat control failure
Symptom
Furnace short cycles; starts and stops frequently without reaching set temperature
Short cycling due to control or airflow issues
Symptom
Furnace starts but shuts down after a few minutes; radiators or ducts only lukewarm
Premature shutdown due to overheating or sensor issues
Symptom
Furnace vibrates excessively and causes rattling noises in ducts
Mechanical vibration / imbalance
Symptom
Furnace will not start at all; no lights or display
No power to furnace
Symptom
Radiators on upper floors stay cold while lower floors heat normally (hydronic IVT furnace/boiler)
Air trapped in heating system
Advertisements