A25
IVT
Flue gas recirculation / combustion air contamination
Furnace indicates flue gas recirculation or CO risk; unit shuts down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Flue outlet too close to air intake, Damaged concentric flue, Negative pressure in boiler room, Blocked combustion air openings
How to Fix / Troubleshooting
Safety: Turn off power and gas immediately. Ventilate the area. If a CO alarm has sounded, evacuate and call emergency services.
- Inspect terminations: Outside, verify that the IVT flue outlet and air intake are correctly spaced and not damaged. Repair or replace any cracked or separated concentric flue components.
- Check room ventilation: Ensure required combustion air openings to the room are not blocked or undersized.
- Assess building pressure: Excessive use of exhaust fans can create negative pressure; reduce their use or provide additional makeup air.
- Professional testing: Have a certified technician perform combustion and draft tests to confirm safe operation before returning the furnace to service.
Do not operate the furnace until the cause of flue gas recirculation is fully resolved.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
IVT concentric flue kit