A24
IVT
Scheduled maintenance reminder
Furnace indicates service interval exceeded; reminder for maintenance
Advertisements
Possible Causes
Elapsed operating hours since last reset, Time-based service interval reached
How to Fix / Troubleshooting
Safety: Even for a reminder, turn off power and gas before performing maintenance.
- Perform basic service:
- Clean or replace air filter.
- Inspect burner and combustion chamber for soot or corrosion.
- Check condensate trap and drain.
- Verify flue and intake are clear.
- Have a full service done: Arrange for an IVT-authorized technician to perform combustion analysis, gas pressure checks, and full safety inspection.
- Reset service timer: After maintenance, use the IVT control menu to reset the service interval according to the manual.
Do not simply reset the reminder without performing the recommended maintenance.
Advertisements
Repair Difficulty
Easy
2/5