F28
Saunier Duval
Ignition Lockout / No Gas Ignition
Furnace shows F28, repeated ignition attempts with clicking but no flame, then lockout
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No gas supply or closed gas cock,Air in gas line after interruption,Faulty ignition electrode or cable,Defective gas valve or no voltage to valve
How to Fix / Troubleshooting
Critical safety warning: If you smell gas, do not attempt to reset the furnace. Ventilate the area and contact emergency gas services.
- User checks: Ensure the gas meter is on, credit is available (if prepay), and the appliance gas isolation valve is fully open.
- Reset after gas interruption: If gas supply was recently restored, there may be air in the line. Follow the manufacturer’s reset procedure and allow several ignition attempts to purge air, under supervision of a gas technician.
- Electrode inspection: A technician should inspect and clean or replace the ignition electrode and cable.
- Gas valve and pressure: A gas engineer must verify inlet pressure, gas valve operation, and burner pressure. Replace the gas valve if it does not open when energized.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Gas Valve Assembly
Check Price on Amazon