Saunier Duval Furnaces Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
F0
Furnace locked out, no heating demand served, display shows F0 and burner does not attempt to ignite
Safety Lockout / Internal Control Fault
F1
Furnace displays F1 and will not start, fan may run briefly then stop, no ignition sequence
Flow Temperature Sensor Fault (NTC Open/Short)
F10
Furnace shows F10, no heating, pump may run briefly then stop
Flow Sensor / Flow Switch Fault
F11
Furnace displays F11, heating stops, may be associated with domestic hot water priority models
DHW Flow Sensor Fault (on combi-type furnace/boiler units)
F12
Furnace shows F12, unit may not respond to user interface commands
User Interface / Display Board Communication Fault
F13
Furnace displays F13, heating may work intermittently, temperature readings appear incorrect
Outdoor Sensor Fault (if fitted) / Auxiliary NTC Fault
F14
Furnace shows F14, burner does not start, may be associated with gas valve control
Gas Valve Control Fault
F15
Furnace displays F15, unit may shut down unexpectedly, sometimes after long operation
Flue Gas Temperature Sensor Fault / Overtemperature
F16
Furnace shows F16, no heating, may occur after power interruptions
Internal EEPROM / Configuration Fault
F2
Furnace shows F2, burner shuts down shortly after starting or does not start, may cycle on/off rapidly
Return Temperature Sensor Fault (NTC Open/Short)
F20
Furnace displays F20, heating stops, pump may continue running
Primary Circuit Overtemperature / Flow Overheat
F22
Furnace shows F22, no heating, may occur after draining or bleeding the system
Dry Fire / Low Water Content Protection
F23
Furnace displays F23, heating stops, may be accompanied by noisy operation
Flow/Return Temperature Differential Too High
F24
Furnace shows F24, rapid temperature rise detected, unit shuts down quickly after start
Pump Blocked / No Circulation
F25
Furnace displays F25, burner shuts down, may be associated with flue gas recirculation
Flue Gas Recirculation / CO Protection
F26
Furnace shows F26, no ignition, may occur after gas valve replacement
Gas Valve Regulation Fault
F27
Furnace displays F27, ignition is blocked, may occur immediately on power-up
Flame Detection Error (False Flame Signal)
F28
Furnace shows F28, repeated ignition attempts with clicking but no flame, then lockout
Ignition Lockout / No Gas Ignition
F29
Furnace displays F29, burner lights briefly then goes out, multiple attempts before lockout
Flame Loss During Operation
F3
Furnace displays F3 and stops, often after running for a short time; casing may feel very hot
Overheat Thermostat Trip / Safety Thermostat Open
F30
Furnace shows F30, no heating, may be associated with room thermostat input
Room Thermostat / External Control Fault
F32
Furnace displays F32, fan speed error, unit may not start or may shut down
Fan Speed Too Low / Fan Control Fault
F37
Furnace shows F37, low system pressure warning, heating may be intermittent
Low Water Pressure
F38
Furnace displays F38, high system pressure warning, safety valve may discharge water
High Water Pressure
F4
Furnace shows F4, no flame established, ignition clicks may be heard but burner does not light
Ignition Failure / No Flame Detection
F41
Furnace shows F41, ignition issues, may be related to incorrect gas type or settings
Incorrect Gas Setting / Combustion Fault
F5
Furnace displays F5, burner shuts down, may occur during operation rather than at startup
Flame Loss During Operation / Flame Signal Fault
F6
Furnace shows F6, fan may run but burner does not light, or unit locks out shortly after start attempt
Air Pressure Switch Fault / Flue Fan Safety
F7
Furnace displays F7, fan may run continuously, burner does not ignite
Fan Speed / Fan Feedback Fault
F8
Furnace shows F8, unit may attempt to start but shuts down quickly, sometimes accompanied by gurgling noises
Low Water Pressure / Water Pressure Sensor Fault
F9
Furnace displays F9, no heating, may occur after power surge or wiring work
External Sensor / Communication Fault
Symptom
Furnace display is on but unresponsive to button presses
Keypad / User Interface Failure
Symptom
Furnace does not start at all, no lights or display, completely dead
No Power / Electrical Supply Failure
Symptom
Furnace emits a burning smell or plastic smell when running
Overheating Component / Electrical Smell
Symptom
Furnace emits a high-pitched whine or humming noise during operation
Fan or Pump Noise / Resonance
Symptom
Furnace fan runs continuously even when there is no heat demand
Fan Overrun / Control Fault
Symptom
Furnace frequently cycles on and off, short burner run times, room temperature unstable
Short Cycling / Oversizing or Control Issue
Symptom
Furnace frequently loses pressure and needs topping up
Chronic Pressure Loss / Leak or Expansion Vessel Failure
Symptom
Furnace makes loud banging or knocking noises when starting or stopping
Water Hammer / Thermal Expansion Noise
Symptom
Furnace runs but radiators remain cold or only lukewarm
Poor Circulation / System Balancing Issue
Symptom
Furnace runs but room never reaches set temperature, especially in cold weather
Underperformance / Sizing or Control Issue
Symptom
Furnace starts then shuts down after a few seconds with a loud whoosh or boom
Delayed Ignition / Burner Light-Back
Symptom
Radiators get hot but domestic hot water temperature is unstable or lukewarm (on combi-type furnace/boiler)
DHW Temperature Control / Plate Heat Exchanger Issue
Symptom
Water dripping from the flue terminal outside
Condensate / Flue Condensation Issue
Symptom
Water leaking from the bottom of the furnace casing
Internal Water Leak
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| F0 |
Furnace locked out, no heating demand served, display shows F0 and burner does not attempt to ignite
|
Safety Lockout / Internal Control Fault | View Details |
| F1 |
Furnace displays F1 and will not start, fan may run briefly then stop, no ignition sequence
|
Flow Temperature Sensor Fault (NTC Open/Short) | View Details |
| F10 |
Furnace shows F10, no heating, pump may run briefly then stop
|
Flow Sensor / Flow Switch Fault | View Details |
| F11 |
Furnace displays F11, heating stops, may be associated with domestic hot water priority models
|
DHW Flow Sensor Fault (on combi-type furnace/boiler units) | View Details |
| F12 |
Furnace shows F12, unit may not respond to user interface commands
|
User Interface / Display Board Communication Fault | View Details |
| F13 |
Furnace displays F13, heating may work intermittently, temperature readings appear incorrect
|
Outdoor Sensor Fault (if fitted) / Auxiliary NTC Fault | View Details |
| F14 |
Furnace shows F14, burner does not start, may be associated with gas valve control
|
Gas Valve Control Fault | View Details |
| F15 |
Furnace displays F15, unit may shut down unexpectedly, sometimes after long operation
|
Flue Gas Temperature Sensor Fault / Overtemperature | View Details |
| F16 |
Furnace shows F16, no heating, may occur after power interruptions
|
Internal EEPROM / Configuration Fault | View Details |
| F2 |
Furnace shows F2, burner shuts down shortly after starting or does not start, may cycle on/off rapidly
|
Return Temperature Sensor Fault (NTC Open/Short) | View Details |
| F20 |
Furnace displays F20, heating stops, pump may continue running
|
Primary Circuit Overtemperature / Flow Overheat | View Details |
| F22 |
Furnace shows F22, no heating, may occur after draining or bleeding the system
|
Dry Fire / Low Water Content Protection | View Details |
| F23 |
Furnace displays F23, heating stops, may be accompanied by noisy operation
|
Flow/Return Temperature Differential Too High | View Details |
| F24 |
Furnace shows F24, rapid temperature rise detected, unit shuts down quickly after start
|
Pump Blocked / No Circulation | View Details |
| F25 |
Furnace displays F25, burner shuts down, may be associated with flue gas recirculation
|
Flue Gas Recirculation / CO Protection | View Details |
| F26 |
Furnace shows F26, no ignition, may occur after gas valve replacement
|
Gas Valve Regulation Fault | View Details |
| F27 |
Furnace displays F27, ignition is blocked, may occur immediately on power-up
|
Flame Detection Error (False Flame Signal) | View Details |
| F28 |
Furnace shows F28, repeated ignition attempts with clicking but no flame, then lockout
|
Ignition Lockout / No Gas Ignition | View Details |
| F29 |
Furnace displays F29, burner lights briefly then goes out, multiple attempts before lockout
|
Flame Loss During Operation | View Details |
| F3 |
Furnace displays F3 and stops, often after running for a short time; casing may feel very hot
|
Overheat Thermostat Trip / Safety Thermostat Open | View Details |
| F30 |
Furnace shows F30, no heating, may be associated with room thermostat input
|
Room Thermostat / External Control Fault | View Details |
| F32 |
Furnace displays F32, fan speed error, unit may not start or may shut down
|
Fan Speed Too Low / Fan Control Fault | View Details |
| F37 |
Furnace shows F37, low system pressure warning, heating may be intermittent
|
Low Water Pressure | View Details |
| F38 |
Furnace displays F38, high system pressure warning, safety valve may discharge water
|
High Water Pressure | View Details |
| F4 |
Furnace shows F4, no flame established, ignition clicks may be heard but burner does not light
|
Ignition Failure / No Flame Detection | View Details |
| F41 |
Furnace shows F41, ignition issues, may be related to incorrect gas type or settings
|
Incorrect Gas Setting / Combustion Fault | View Details |
| F5 |
Furnace displays F5, burner shuts down, may occur during operation rather than at startup
|
Flame Loss During Operation / Flame Signal Fault | View Details |
| F6 |
Furnace shows F6, fan may run but burner does not light, or unit locks out shortly after start attempt
|
Air Pressure Switch Fault / Flue Fan Safety | View Details |
| F7 |
Furnace displays F7, fan may run continuously, burner does not ignite
|
Fan Speed / Fan Feedback Fault | View Details |
| F8 |
Furnace shows F8, unit may attempt to start but shuts down quickly, sometimes accompanied by gurgling noises
|
Low Water Pressure / Water Pressure Sensor Fault | View Details |
| F9 |
Furnace displays F9, no heating, may occur after power surge or wiring work
|
External Sensor / Communication Fault | View Details |
| – |
Furnace display is on but unresponsive to button presses
|
Keypad / User Interface Failure | View Details |
| – |
Furnace does not start at all, no lights or display, completely dead
|
No Power / Electrical Supply Failure | View Details |
| – |
Furnace emits a burning smell or plastic smell when running
|
Overheating Component / Electrical Smell | View Details |
| – |
Furnace emits a high-pitched whine or humming noise during operation
|
Fan or Pump Noise / Resonance | View Details |
| – |
Furnace fan runs continuously even when there is no heat demand
|
Fan Overrun / Control Fault | View Details |
| – |
Furnace frequently cycles on and off, short burner run times, room temperature unstable
|
Short Cycling / Oversizing or Control Issue | View Details |
| – |
Furnace frequently loses pressure and needs topping up
|
Chronic Pressure Loss / Leak or Expansion Vessel Failure | View Details |
| – |
Furnace makes loud banging or knocking noises when starting or stopping
|
Water Hammer / Thermal Expansion Noise | View Details |
| – |
Furnace runs but radiators remain cold or only lukewarm
|
Poor Circulation / System Balancing Issue | View Details |
| – |
Furnace runs but room never reaches set temperature, especially in cold weather
|
Underperformance / Sizing or Control Issue | View Details |
| – |
Furnace starts then shuts down after a few seconds with a loud whoosh or boom
|
Delayed Ignition / Burner Light-Back | View Details |
| – |
Radiators get hot but domestic hot water temperature is unstable or lukewarm (on combi-type furnace/boiler)
|
DHW Temperature Control / Plate Heat Exchanger Issue | View Details |
| – |
Water dripping from the flue terminal outside
|
Condensate / Flue Condensation Issue | View Details |
| – |
Water leaking from the bottom of the furnace casing
|
Internal Water Leak | View Details |