F9
Saunier Duval External Sensor / Communication Fault

Furnace displays F9, no heating, may occur after power surge or wiring work

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty room thermostat or eBUS controller,Incorrect wiring of external controls,Open or short circuit on communication bus,Defective main control PCB communication circuit

How to Fix / Troubleshooting

Safety first: Turn off power before working on control wiring. Low-voltage circuits can still be damaged by shorts.

  • Check external controls: If using a Saunier Duval eBUS room thermostat or controller, verify that it powers up and displays correctly. Replace batteries if applicable.
  • Inspect wiring: Open the control terminal block on the furnace and check that thermostat/eBUS wires are correctly connected as per the wiring diagram. Look for loose strands or shorts between terminals.
  • Test without external control: If possible, temporarily disconnect the external controller and fit a simple link (if allowed by the manual) to simulate a call for heat. If F9 clears, the issue is likely with the external device or its wiring.
  • Bus polarity and type: Ensure that only compatible Saunier Duval eBUS devices are connected to the eBUS terminals and that polarity is correct where required.
  • PCB replacement: If wiring and external devices are confirmed good, the main PCB’s communication circuit may be defective and require replacement by an authorized technician.