F29
Saunier Duval Flame Loss During Operation

Furnace displays F29, burner lights briefly then goes out, multiple attempts before lockout

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable gas supply pressure,Blocked burner or injector,Faulty ionization electrode,Flue issues causing flame instability

How to Fix / Troubleshooting

Safety first: Only a qualified gas technician should work on burner and gas components.

  • Check gas supply stability: A gas engineer should measure inlet pressure during operation to ensure it remains within Saunier Duval limits.
  • Clean burner: Remove and clean the burner and injectors to remove dust, rust, or debris that can cause poor flame stability.
  • Inspect ionization electrode: Clean or replace the electrode and ensure correct positioning in the flame.
  • Flue inspection: Verify that the flue system is intact and not causing downdrafts or recirculation that could extinguish the flame.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Burner Assembly
Check Price on Amazon