F37
Saunier Duval
Low Water Pressure
Furnace shows F37, low system pressure warning, heating may be intermittent
Advertisements
Possible Causes
Insufficient filling of heating system,Small leak in system pipework,Faulty pressure gauge or sensor,Automatic air vent releasing air and pressure
How to Fix / Troubleshooting
Safety first: Allow the system to cool before topping up. Do not exceed the maximum pressure indicated on the gauge.
- Top up pressure: Use the filling loop to raise pressure to the recommended cold value (usually 1.0–1.5 bar). Close the filling valves securely afterwards.
- Bleed radiators: Remove trapped air from radiators and recheck pressure.
- Check for leaks: Inspect radiators, valves, and visible pipework for signs of water. Persistent pressure loss requires leak repair.
- Sensor check: If pressure is correct but F37 persists, the pressure sensor or gauge may be faulty and should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Pressure Sensor
Check Price on Amazon