F37
Saunier Duval Low Water Pressure

Furnace shows F37, low system pressure warning, heating may be intermittent

Advertisements

Possible Causes

Insufficient filling of heating system,Small leak in system pipework,Faulty pressure gauge or sensor,Automatic air vent releasing air and pressure

How to Fix / Troubleshooting

Safety first: Allow the system to cool before topping up. Do not exceed the maximum pressure indicated on the gauge.

  • Top up pressure: Use the filling loop to raise pressure to the recommended cold value (usually 1.0–1.5 bar). Close the filling valves securely afterwards.
  • Bleed radiators: Remove trapped air from radiators and recheck pressure.
  • Check for leaks: Inspect radiators, valves, and visible pipework for signs of water. Persistent pressure loss requires leak repair.
  • Sensor check: If pressure is correct but F37 persists, the pressure sensor or gauge may be faulty and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Pressure Sensor
Check Price on Amazon