E14
Termet Room Thermostat / Control Signal Fault

Display shows E14, furnace may not respond to thermostat commands.

Advertisements

Possible Causes

Open circuit in room thermostat wiring, Incorrect thermostat settings, Faulty room thermostat, Misconfigured Termet control parameters

How to Fix / Troubleshooting

Safety: Turn off power before working on control wiring.

  • Check thermostat wiring: At the Termet control board, verify that the room thermostat terminals (e.g., TA/TB) are correctly wired and tight. Inspect the cable for damage.
  • Bypass test (low-voltage only): Temporarily bridge the thermostat terminals at the furnace with a short wire. If the furnace starts, the thermostat or its cable is faulty.
  • Verify thermostat settings: Ensure the thermostat is set to HEAT mode and the setpoint is above room temperature.
  • Check control parameters: In the Termet installer menu (if accessible), verify that the control mode matches the installed thermostat type (on/off vs. OpenTherm, etc.).

If E14 persists with correct wiring and a known-good thermostat, the control board may require replacement by a professional.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Room Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements