Termet No Power / Dead Furnace

Furnace will not start at all; display is blank or dark, no fan or pump operation.

Advertisements

Possible Causes

Tripped circuit breaker, Blown internal fuse on Termet PCB, Loose mains wiring at terminal block, Failed main control board power supply

How to Fix / Troubleshooting

Safety: Turn off the breaker before opening any electrical compartment.

  • Check breaker and switch: Verify the furnace circuit breaker is ON and any local disconnect switch near the Termet furnace is ON.
  • Inspect power cord/terminal: Open the electrical access panel and confirm that live, neutral, and earth are securely connected.
  • Check internal fuse: Many Termet boards have a replaceable fuse. With power off, remove and visually inspect the fuse. Replace only with the same type and rating.
  • Test outlet (if plug-in): Plug another device into the same outlet to confirm power is present.

If the furnace remains dead after these checks, the main control board or internal power supply is likely faulty and should be replaced by a professional.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.