F20
Viessmann Safety interlock / limit circuit open

Safety chain open, boiler will not start, safety loop error

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open high-limit thermostat, Tripped flue gas thermostat, Open safety pressure switch, Loose wiring in safety loop

How to Fix / Troubleshooting

Safety: Do not bypass any safety devices. Identify and correct the root cause.

  • Visual check of safety devices: Locate the high-limit thermostat, flue gas thermostat, and any external safety switches wired in series. Check for manual reset buttons and press once if tripped.
  • Inspect wiring: Follow the safety loop wiring and ensure all spade connectors are tight and not corroded.
  • Check system conditions: A tripped safety often indicates overheating or flue issues. Verify pumps are running and flue is clear.
  • Reset and test: After addressing the cause, reset the boiler. If F20 returns, a technician should test each safety device individually.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

High-Limit Thermostat
Check Price on Amazon

We may earn a commission from links on this page.