Viessmann

Viessmann Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
F1
Burner lockout, furnace will not start, red fault LED on control, no flame established
Ignition failure / no flame signal
F10
Low system pressure warning, boiler may not fire or may shut down frequently
Low water pressure / insufficient system fill
F11
High system pressure fault, pressure gauge near or above 3 bar, safety valve may discharge water
Overpressure / expansion vessel or fill fault
F12
Fan speed error, boiler does not ignite, fan either not running or running at incorrect speed
Combustion fan / speed feedback fault
F13
Condensate fault, boiler shuts down with drain or condensate error, possible gurgling noises
Condensate drainage blockage
F14
Gas valve error, boiler does not fire, control indicates gas valve or modulation fault
Gas valve control / modulation fault
F15
Communication error between main control and user interface or external Vitotronic module
Control bus communication fault
F16
Domestic hot water (DHW) temperature sensor error on combi or indirect systems
DHW sensor fault
F17
Flow switch or flow sensor error on combi boiler, no hot water despite demand
DHW flow detection fault
F18
Power supply or internal voltage error, boiler may reboot or lock out intermittently
Internal power supply / low voltage fault
F19
Sensor plausibility error, temperature readings inconsistent or out of range
Sensor plausibility / multiple sensor disagreement
F2
Furnace attempts to start but shuts down quickly, control shows flame error, intermittent heating
Flame detection fault / unstable flame signal
F20
Safety chain open, boiler will not start, safety loop error
Safety interlock / limit circuit open
F22
Dry fire / low water content detected, boiler shuts down quickly after start
Low water content / dry firing protection
F23
Flow/return temperature difference too high, boiler shuts down to protect heat exchanger
Insufficient circulation / high delta-T fault
F24
Rapid temperature rise detected, boiler shuts down shortly after burner starts
Overtemperature / poor circulation fault
F25
Flue gas temperature too high, boiler shuts down with flue overheat fault
Flue gas overtemperature / heat exchanger fouling
F26
Gas valve modulation error, boiler may run only at low power or not at all
Gas valve modulation / actuator fault
F27
Flame detected when there should be none, boiler locks out for safety
False flame detection / ionization fault
F28
Ignition attempt fails, no flame established, multiple retries then lockout
No ignition / gas supply fault
F29
Flame lost during operation, boiler shuts down with flame failure code
Flame dropout / unstable combustion
F3
Furnace locks out with overheat indication, supply temperature extremely high, burner stops
High-limit temperature trip / safety temperature limiter (STB) activated
F30
Room thermostat or external demand signal error, boiler does not respond to heat calls
External control / thermostat fault
F4
No ignition, control shows ignition fault, burner does not light at all
Ignition transformer or ignition circuit failure
F5
Furnace shuts down with flue gas sensor error, may run briefly then lock out
Flue gas temperature sensor fault
F6
Furnace displays supply temperature sensor error, unit may not fire or may run erratically
Flow temperature sensor fault
F7
Return temperature sensor error, boiler may short-cycle or shut down
Return temperature sensor fault
F8
Outdoor temperature sensor error on systems with Viessmann weather-compensated control, heating curve not working
Outdoor sensor circuit fault
F9
Furnace shows flue gas recirculation or combustion air fault, may shut down with safety lockout
Combustion air / flue gas recirculation fault
Symptom
Boiler display is blank or intermittently turns off, but mains power is present
Control power / display fault
Symptom
Boiler locks out frequently during windy conditions, especially with sidewall flue
Wind-induced flue disturbance
Symptom
Condensate pipe outside frequently freezes in cold weather, causing boiler shutdowns
Frozen condensate discharge
Symptom
Domestic hot water temperature fluctuates or is too hot/cold on a Viessmann combi or indirect system
DHW temperature control issue
Symptom
Furnace emits unusual smells (burning dust, metallic, or flue gas odor) during operation
Odor / combustion or contamination issue
Symptom
Furnace is running but some radiators remain cold or only partially warm
Hydronic balancing / circulation issue
Symptom
Furnace makes loud banging or knocking noises when starting or stopping (kettling)
Boiler kettling / localized boiling in heat exchanger
Symptom
Furnace runs but house does not reach set temperature, long run times with poor heat output
Underfiring / incorrect boiler output
Symptom
Furnace short cycles (frequent on/off) without maintaining stable temperature
Short cycling / control or sizing issue
Symptom
Furnace vibrates excessively or makes humming/rumbling noises during operation
Mechanical vibration / mounting issue
Symptom
Radiators get hot even when there is no call for heat from the thermostat
Unwanted heating / valve or control fault
Symptom
System pressure drops to zero over days or weeks, requiring frequent topping up
Chronic pressure loss / leak or expansion fault
Symptom
Water leaking from the bottom of the Viessmann furnace or from attached pipework
System water leak / condensate or heating circuit leak