F30
Viessmann
External control / thermostat fault
Room thermostat or external demand signal error, boiler does not respond to heat calls
Advertisements
Possible Causes
Open-circuit room thermostat, Incorrect wiring to Viessmann control terminals, Faulty relay in external controller, Broken low-voltage cable
How to Fix / Troubleshooting
Safety: Turn off power before working on control wiring.
- Check thermostat: Ensure the room thermostat or Viessmann Vitotrol is powered and set above room temperature.
- Inspect wiring: At the boiler, check the thermostat or demand terminals (e.g., 3 and 4). Verify that the wires are secure and not broken.
- Bypass test (only if safe and allowed): Temporarily link the thermostat terminals at the boiler to simulate a call for heat. If the boiler starts, the issue is with the thermostat or its wiring.
- Restore normal wiring: Remove any test links and reconnect the thermostat correctly.
- Replace faulty control: If the thermostat is unresponsive, replace it with a compatible Viessmann-approved control.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat / Vitotrol Controller
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements