F9
Viessmann
Combustion air / flue gas recirculation fault
Furnace shows flue gas recirculation or combustion air fault, may shut down with safety lockout
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked concentric flue terminal, Incorrect flue installation causing recirculation, Damaged flue seals on Viessmann flue system, Strong wind effects on terminal
How to Fix / Troubleshooting
Safety: Shut down the boiler and do not operate it if flue gas recirculation is suspected. Risk of carbon monoxide.
- Inspect terminal: From outside, check the Viessmann concentric flue terminal for obstructions (snow, ice, leaves, nests). Clear any blockage carefully.
- Check flue joints: Visually inspect accessible flue sections for dislodged or separated joints. Ensure all locking bands and seals are intact.
- Check air intake: On systems with separate air intake, verify that the intake is not blocked or drawing from a contaminated area.
- Wind effects: If the fault occurs only during strong winds, a terminal deflector or relocation may be required; consult a Viessmann-trained installer.
- Do not modify flue yourself: Any flue reconfiguration must be done by a qualified technician following Viessmann flue design guidelines.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Viessmann Concentric Flue Kit