E05
Weishaupt Overtemperature / safety thermostat trip

Burner does not start, display indicates overtemperature or safety limit trip

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped manual reset high-limit thermostat, Blocked heat exchanger or flue, Circulation pump failure (for boiler/furnace with water circuit), Faulty temperature sensor

How to Fix / Troubleshooting

Safety: Allow the furnace to cool completely. Turn off power before removing any covers.

Steps:

  • Check system circulation: Ensure that all heating zone valves are open and that the circulation pump (if present) is running when there is a call for heat. Listen for pump operation or feel for vibration.
  • Inspect air filters and ducts (warm air furnace): Replace clogged air filters and ensure supply/return grilles are not blocked.
  • Reset high-limit thermostat: Locate the manual reset high-limit on the furnace or boiler body (often a red button). Press firmly until it clicks. If it trips again, do not continue resetting—there is an underlying overheating problem.
  • Check flue and heat exchanger: Visually inspect for obvious blockages in the flue path. Do not dismantle sealed combustion components unless qualified.

If E05 recurs, contact a Weishaupt service technician to inspect the heat exchanger, circulation system, and temperature sensors.

Advertisements

Repair Difficulty

Hard 4/5