E06
Weishaupt Temperature sensor (NTC) failure

Control shows sensor fault, burner does not start or runs erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted flow temperature sensor, Faulty flue gas temperature sensor, Damaged sensor wiring harness, Defective control input on WCM/W-FM

How to Fix / Troubleshooting

Safety: Disconnect power before accessing the control panel or sensors.

Steps:

  • Locate sensors: Identify the flow/boiler temperature sensor and flue gas sensor on the Weishaupt furnace or boiler. They are typically NTC probes inserted into wells or clipped to pipes.
  • Visual inspection: Check that the sensor bodies are firmly seated and that cables are not pinched, cut, or burned.
  • Connector check: At the WCM or W-FM control, gently unplug and replug the sensor connectors to ensure good contact.
  • Resistance check (qualified persons): Measure sensor resistance at room temperature and compare to Weishaupt NTC tables. Replace any sensor that is open, shorted, or out of range.

After replacing a sensor, clear the error by cycling power or using the controller reset function.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flow Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements