E07
Weishaupt Fuel valve actuation failure

Burner locks out with indication of gas valve or oil valve fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve coil, Faulty oil solenoid valve, Broken wiring between control and valve, Internal valve blockage

How to Fix / Troubleshooting

Safety: Shut off fuel supply and power. Work on gas or oil valves only if you are trained; otherwise, call a professional.

Basic checks:

  • Listen for valve operation: During a start attempt (with covers in place), you should hear a click from the gas or oil valve. No click may indicate a coil or control issue.
  • Inspect wiring: With power off, check the plug connectors on the Weishaupt gas valve train or oil solenoid valves. Ensure they are fully seated and not corroded.
  • Check manual shutoff: Confirm that any manual shutoff on the valve body is open.

Technician tasks: Measure coil resistance, verify voltage at the valve during start, and replace the valve or coil if defective. Gas valve replacement must be followed by leak testing and combustion adjustment.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements