E10
Weishaupt
Air pressure switch not proving
Burner locks out with indication of air pressure switch open
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked fan housing or venturi, Faulty air pressure switch, Disconnected or leaking pressure tubing, Fan speed too low
How to Fix / Troubleshooting
Safety: Turn off power before removing burner covers.
Steps:
- Check tubing: Inspect the silicone tubes between the fan housing and the air pressure switch. Replace any that are brittle, cracked, or loose.
- Clean fan intake: Remove dust and debris from the fan inlet and venturi on the Weishaupt burner. Ensure the air damper moves freely.
- Switch test (basic): Gently tap the pressure switch body; sometimes a stuck diaphragm may release. If the error clears temporarily, the switch is likely failing and should be replaced.
Persistent E10 faults require a technician to verify fan speed, switch setpoint, and replace the air pressure switch if necessary.