E20
Weishaupt Condensate drainage failure

Burner shuts down with indication of condensate fault (for condensing units)

Advertisements

Possible Causes

Blocked condensate trap, Frozen or kinked condensate hose, Faulty condensate level switch, Improper condensate drain slope

How to Fix / Troubleshooting

Safety: Turn off power. Condensate is mildly acidic; wear gloves and eye protection.

Steps:

  • Inspect trap: Locate the condensate trap on the furnace. Remove and clean it of sludge and debris. Refill with clean water before reinstalling.
  • Check hose: Ensure the condensate hose is not kinked, frozen, or blocked. Clear any obstruction and verify proper downward slope to the drain.
  • Level switch: If equipped with a condensate float or level switch, check that it moves freely and is not stuck by dirt.

After cleaning, restore power and test operation. Persistent faults may require switch replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Trap
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements