Possible Causes
Faulty room thermostat, Broken thermostat wiring, Incorrect controller configuration, Open safety interlock not indicated as error
How to Fix / Troubleshooting
Safety: Low-voltage thermostat circuits are generally safe, but always turn off power before working on wiring.
Steps:
- Verify thermostat: Increase the setpoint and ensure the thermostat display indicates a call for heat.
- Bypass test (qualified): Temporarily bridge the thermostat terminals at the WCM or junction box to see if the burner starts. If it does, the thermostat or its wiring is faulty.
- Configuration: Check that the correct operating mode and schedules are set on the WCM controller.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Thermostat