FAAC
Power Supply or Fuse Failure After Surge
Opener does not respond after a power outage; no lights or signs of life.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown main fuse, Damaged transformer from surge, Tripped external breaker, Loose mains connection in FAAC terminal block
How to Fix / Troubleshooting
Safety: Turn off the breaker before opening the unit. Use a non-contact tester to confirm power is off.
- Check external power: Verify the breaker or fuse feeding the opener has not tripped. Reset if necessary.
- Inspect internal fuse: Open the FAAC housing and locate the main fuse. Replace with the same rating if blown.
- Check mains terminals: Ensure the live, neutral, and earth wires are securely clamped in the FAAC terminal block.
- Test transformer: If comfortable and qualified, measure the transformer output. No output indicates a failed transformer that must be replaced.
If multiple components appear damaged after a surge, replacing the entire control board assembly is often more economical.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
FAAC Main Fuse
Check Price on Amazon
We may earn a commission from links on this page.