E14
Novoferm Courtesy light circuit fault

Novoferm garage door opener shows E14 and the integrated light does not function correctly.

Advertisements

Possible Causes

Shorted light socket or LED module, Incorrect bulb type drawing too much current, Burnt triac or relay on control board, Wiring fault to light holder

How to Fix / Troubleshooting

Safety first: Disconnect mains power before changing bulbs or accessing the light holder.

Steps to try:

  • Check bulb type: Ensure you are using the bulb type and wattage specified by Novoferm. Replace any non‑approved LED or high‑wattage lamps.
  • Inspect light holder: Remove the cover and check the lamp holder for signs of heat damage, corrosion, or loose contacts.
  • Test without bulb: Remove the bulb and power up. If E14 clears, the bulb or holder may be shorted. Try a new, correct bulb.

If E14 persists with a correct bulb and intact holder, the light control circuit on the PCB is likely damaged. The control board may need replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Novoferm light holder / lamp
Check Price on Amazon

We may earn a commission from links on this page.