P1
Coleman Pump 1 Drive or Overload Fault

Display shows P1 flashing, first jet pump does not start or runs erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 1 motor, Tripped thermal overload on Pump 1, Loose pump wiring at control pack, Failed pump relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before touching the pump or wiring.

  • 1. Check for obstructions: Remove the pump access panel and inspect around Pump 1 (primary jet pump). Ensure no debris is blocking the impeller or shaft.
  • 2. Spin the shaft: If accessible, try to rotate the pump shaft by hand with power off. A seized shaft indicates the pump needs replacement.
  • 3. Inspect wiring: Verify that Pump 1's wires are securely connected to the control pack terminals and show no signs of burning.
  • 4. Thermal overload: Allow the pump to cool for 30–60 minutes, then restore power and try again. If it runs briefly then trips again, the motor is likely failing.
  • 5. Relay/board fault: If the pump tests good but never receives power, the Pump 1 relay on the control board may be defective and the board will need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 1
Check Price on Amazon

We may earn a commission from links on this page.