P2
Coleman Pump 2 Drive or Overload Fault

Display shows P2 flashing, second jet pump does not start or trips breaker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted Pump 2 motor windings, Incorrect voltage wiring for Pump 2, Loose or burned connectors, Failed Pump 2 relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker. Pump electrical testing should be done by a qualified person.

  • 1. Visual inspection: Check Pump 2 for signs of overheating, water leaks into the motor, or burned wiring.
  • 2. Wiring verification: Confirm Pump 2 is wired according to the Coleman wiring diagram (correct 120/240V configuration).
  • 3. Isolation test: Disconnect Pump 2 from the control pack and restore power. If the error or breaker tripping stops, Pump 2 is likely defective and should be replaced.
  • 4. Control board check: If P2 persists with the pump disconnected, the control board relay or output circuit is likely faulty and requires replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Jet Pump 2
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements