Coleman Spa Lighting Circuit Failure

LED lights flicker, some colors do not work, or lights are completely out.

Advertisements

Possible Causes

Failed LED light module, Loose light harness connection, Water intrusion into light housing, Faulty low-voltage driver on control board

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before working on lighting components.

  • 1. Check light settings: Cycle through light modes from the topside to ensure it's not a programming issue.
  • 2. Inspect light lenses: Look for condensation or water behind the Coleman light lenses. If present, the light module may be compromised.
  • 3. Harness check: Access the back of the light niche from inside the cabinet and verify the light harness is securely connected.
  • 4. Replace LED module: If a single light is out or discolored, replace that LED module with a compatible Coleman part.
  • 5. Driver/board fault: If all lights are out and modules test good, the low-voltage lighting driver on the control board may have failed and the board may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.