Coleman No-Heat Condition Without Error

Spa will not heat, temperature stays far below set point but no error code is displayed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially failed heater element, Weak circulation through heater, Misconfigured heating mode (EC/SL), Temperature sensor out of calibration

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before opening the equipment bay.

  • 1. Verify mode and set point: Confirm the spa is in Standard mode and the set temperature is higher than current water temperature.
  • 2. Check heater indicator: On the Coleman topside, look for a heat icon or indicator. If it never appears, the control pack may not be calling for heat due to sensor misreadings.
  • 3. Confirm circulation: Ensure strong flow from the heater return. Clean the filter and bleed air from the pump and heater unions.
  • 4. Sensor comparison: Compare displayed temperature to a thermometer. If off by more than a few degrees, replace the temperature sensor.
  • 5. Heater and board testing: A technician should test heater resistance and verify voltage at the heater terminals when heat is called. Replace the heater assembly or control board as indicated by test results.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heater Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements