PF
MAAX Spas
Power Failure / Brownout Detected
Display shows PF or POWER FAIL; spa has lost its previous settings and may be in default mode.
Advertisements
Possible Causes
Recent power outage, Loose GFCI breaker connection, Undersized supply wiring to MAAX spa, Faulty main power relay on control board
How to Fix / Troubleshooting
Safety: Always turn off the main breaker before tightening electrical connections.
- Check household power: Verify that the GFCI breaker feeding the spa is fully on and not tripped.
- Inspect connections: With power off, open the MAAX control pack and check that all incoming power lugs are tight.
- Restore settings: Reprogram the time, temperature, and filtration cycles as needed.
- Monitor for repeats: If PF appears frequently without known outages, have an electrician check supply voltage and connections.