Sn1
MAAX Spas Water Temperature Sensor Fault

Display shows Sn1 or SN1 and spa may not heat or may shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed thermistor sensor, Loose or corroded sensor connector on control board, Damaged sensor cable, Sensor not fully seated in the MAAX heater well

How to Fix / Troubleshooting

Safety: Disconnect power before accessing the control pack or heater.

  • Locate the sensor: In most MAAX Spas, the water temperature sensor (thermistor) is threaded into the heater tube or inserted into a sensor well.
  • Check connections: Open the equipment bay and verify the sensor plug is firmly seated on the control board and free of corrosion.
  • Inspect cable: Look for cuts, rodent damage, or pinched sections along the sensor wire.
  • Reseat sensor: If the sensor is in a dry well, remove it, wipe off any moisture or corrosion, and reinsert fully. Use a small amount of thermal compound if recommended by MAAX.
  • Power cycle: Restore power and see if Sn1 clears. If the error returns, the sensor resistance is likely out of range.
  • Replace sensor: Install a MAAX-compatible temperature sensor/thermistor, matching the original part number. Do not substitute with non-rated sensors.