PDC Spas
Air induction failure
Air controls do not introduce air into jets; jets feel flat with only water flow.
Advertisements
Possible Causes
Stuck or clogged air control valves, Blocked air intake lines, Waterlogged air check valves, Air control internals deteriorated
How to Fix / Troubleshooting
Safety first: Turn off power at the GFCI breaker before disassembling air controls.
- 1. Operate air controls: Turn the air control knobs fully open and closed several times to free any sticking parts.
- 2. Inspect air intakes: Locate the air intake openings on the spa shell and ensure they are not blocked by debris or covers.
- 3. Remove and clean valves: If accessible, remove the air control valve tops and clean any debris or scale. Replace worn O-rings or internals.
- 4. Replace faulty controls: If air still does not enter the jets, replace the PDC Spas air control valves with compatible units.