PDC Spas Ozone generator failure or injector blockage

Ozone indicator is on but there is no ozone smell or visible bubbles from ozone injector.

Advertisements

Possible Causes

Expired or failed PDC Spas ozone generator, Cracked or kinked ozone tubing, Blocked Mazzei injector or check valve, Ozone check valve installed backwards

How to Fix / Troubleshooting

Safety first: Turn off power at the GFCI breaker before handling ozone equipment. Avoid inhaling concentrated ozone.

  • 1. Inspect tubing: Check ozone tubing from the generator to the injector for kinks, cracks, or disconnections. Replace brittle tubing.
  • 2. Check check valve: Ensure the ozone check valve is oriented correctly (arrow pointing toward the injector) and not blocked.
  • 3. Clean or replace injector: If there are no bubbles at the injector port, the injector may be clogged with scale. Remove and soak in a descaling solution or replace with a compatible injector.
  • 4. Replace ozone generator: Ozone units typically have a limited lifespan (2–4 years). If older, replace with a PDC Spas-compatible ozone generator.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

PDC Spas ozone generator
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements