QCA Spas
No Heat Condition
Spa does not heat, water stays at or near ambient temperature even though pumps run and set temperature is higher.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed heater element, Tripped high-limit sensor, Faulty temperature sensor misreading water temp, Heater relay failure on control board
How to Fix / Troubleshooting
Safety: Turn off power and verify with a tester before touching heater wiring.
- Confirm settings: Ensure the spa is in Standard mode (not Economy) and the set temperature is above current water temperature.
- Check for OH/HL codes: If overheat codes appear, resolve flow issues first.
- Test heater element: With power OFF and wires removed from the heater, measure resistance across the heater terminals. Replace the QCA Spas heater assembly if the element is open or shorted.
- Inspect control board: If the heater tests good but never receives power when the heat icon is on, the heater relay or control board may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Heater Assembly
Check Price on Amazon
We may earn a commission from links on this page.