dSP
Vita Spa Topside Display Communication Error

Display shows dSP or DSP; topside panel may be blank or show partial characters.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged topside ribbon cable, Water intrusion into topside control, Faulty display driver on control board

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI before unplugging the topside panel.

  • Step 1 – Inspect cable: Remove the topside panel bezel and gently pull the ribbon cable. Check for corrosion, kinks, or cuts. Reseat both ends at the panel and control pack.
  • Step 2 – Dry moisture: If condensation or water is present under the topside overlay, dry the area thoroughly. Persistent moisture usually requires panel replacement.
  • Step 3 – Substitute panel: If available, test with a known-good Vita Spa topside panel to determine whether the fault is in the panel or the control pack.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Topside Control Panel
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements