P1
Vita Spa Pump 1 Circuit Fault

Display shows P1 ERR or P1 error; Pump 1 does not start or trips breaker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized Pump 1 motor, Shorted pump windings, Loose or burned pump connector at control pack, Incorrect voltage configuration

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI. Pumps draw high current; use caution.

  • Step 1 – Check for obstructions: Ensure all slice valves are open and there are no kinks in the suction or return lines for Pump 1.
  • Step 2 – Try to spin shaft: With power off, remove the rear motor cover and attempt to spin the shaft by hand. If seized, the pump will need replacement.
  • Step 3 – Inspect wiring: Check the Pump 1 connector at the Vita Spa control pack for heat damage or loose pins. Repair as needed.
  • Step 4 – Electrical test: A technician can test pump windings for shorts and verify correct voltage output from the control pack.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Jet Pump 1
Check Price on Amazon