Prr
Vita Spa
Priming Mode / Pump Priming Reminder
Display shows PRR or Prr; spa may not start normal heating or filtration cycles.
Advertisements
Possible Causes
Spa just powered up, Air in pump and plumbing, System waiting for user to prime pumps
How to Fix / Troubleshooting
Safety: Ensure all jets are open and slice valves are fully raised before running pumps.
- Step 1 – Open jets: Turn all jet faces fully counterclockwise to open.
- Step 2 – Run pumps: Use the topside control to turn each pump on and off several times to purge air. You should see strong water flow from jets.
- Step 3 – Bleed unions if needed: If a pump only hums, turn off power and slightly loosen the union on the pump discharge to release trapped air, then retighten and retry.
- Step 4 – Exit priming mode: After priming, the spa will automatically exit PRR mode or you may need to press a specific button per the Vita Spa manual.
Advertisements
Repair Difficulty
Easy
2/5