SE
Vita Spa Sensor or System Error (General)

Display shows SE or SEr; spa may not respond correctly to button presses or may reboot unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Firmware glitch in control pack, Loose ribbon cable between topside and control board, Electrical noise or surge

How to Fix / Troubleshooting

Safety: Turn off power at the GFCI before unplugging any cables.

  • Step 1 – Power reset: Turn off power for 5–10 minutes, then restore. Observe if SE returns.
  • Step 2 – Check topside cable: Inspect the ribbon cable from the topside control to the Vita Spa control pack for damage or corrosion. Reseat both ends firmly.
  • Step 3 – Inspect ground and bonding: Ensure the spa pack is properly grounded and bonded per Vita Spa installation instructions to reduce electrical noise.
  • Step 4 – Firmware/board: Persistent SE errors may require control pack replacement or firmware update by an authorized Vita Spa technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Control Pack
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements