Vita Spa
No Power / Dead Spa
Spa will not power on at all; topside display is completely blank and no pumps run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped GFCI breaker, Loose main power connections at Vita Spa control pack, Blown internal fuse on control board, Failed control pack
How to Fix / Troubleshooting
Safety: Only qualified persons should work inside electrical panels. Always turn off power before opening the spa equipment bay.
- Step 1 – Check GFCI: Locate the spa's GFCI breaker and ensure it is fully in the ON position. If tripped, reset once. If it trips immediately, there is a fault that needs diagnosis.
- Step 2 – Inspect main connections: With breaker OFF, open the Vita Spa equipment bay and verify that all line and neutral wires are tight at the control pack terminals.
- Step 3 – Internal fuses: Many Vita Spa packs have internal fuses. Remove the control pack cover and visually inspect fuses; test with a multimeter and replace only with identical ratings.
- Step 4 – Further diagnosis: If power is present at the pack but the system is dead, the control board may have failed and require replacement.
Advertisements
Repair Difficulty
Hard
4/5