Vita Spa
Failed Topside Control Membrane
Topside control buttons are unresponsive or only some buttons work intermittently (no LOC code).
Advertisements
Possible Causes
Worn keypad membrane, Water intrusion under overlay, Damaged ribbon cable
How to Fix / Troubleshooting
Safety: Turn off power before removing the topside panel.
- Step 1 – Inspect overlay: Look for cracks, bubbles, or water under the keypad overlay. Moisture often causes intermittent operation.
- Step 2 – Check cable: Remove the panel and inspect the ribbon cable for corrosion or damage. Clean contacts and reseat.
- Step 3 – Replace panel: If issues persist, replace the topside control panel with the correct Vita Spa model.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Topside Control Panel
Check Price on Amazon