F1
Argo
Low Ambient Temperature Protection / Anti-Frost Mode
F1 appears and the fan runs but compressor does not engage.
Advertisements
Possible Causes
Room temperature below operating range, Faulty ambient temperature sensor reading too low, Control logic stuck in defrost mode
How to Fix / Troubleshooting
Safety: No internal work is usually required for this condition, but always unplug the unit before opening any covers.
Steps:
- Check room temperature: Verify that the room is within the operating range specified by Argo (typically above 5–7°C for dehumidifiers). If the room is too cold, move the unit to a warmer area.
- Allow warm-up: If the unit was stored in a cold environment, let it sit unplugged at room temperature for several hours before use.
- Sensor check: If F1 appears even in a warm room, inspect the ambient NTC sensor and wiring. Replace the Argo ambient NTC temperature sensor if it reads abnormally low resistance.
- Reset control: After sensor replacement or relocation to a warmer room, unplug and reconnect power to clear the fault.
Advertisements
Repair Difficulty
Easy